From HFML-FELIX Wiki
Jump to: navigation, search
FEL2
Beam
Energy 45 MeV
Undulator
period (λu) 65 mm
no. periods 38
KRMS (range) 0.4–1.9

FELIX-2, or FEL2, is the mid-Infrared or short-wavelength beam line of FELIX operating from 3–45 µm.

Spectral Range vs. Beam Energy

[edit | edit source]
Typical power curve for 45 MeV at 1.7 λ detuning.
Beam Energy [MeV] Min [µm] Max [µm] Min [cm-1] Max [cm-1] Max pulse width [µs]
27.5 13.1 50 200 763 12
30 11 42 238 909 12
31.4 10.1 38.5 259 990 11
38 6.9 26.3 380 1449 10
44 5.5 19.6 510 1818 9
45.5 5 18.3 545 2000 8
47 4.8 17 588 2083 8


Procedures

[edit | edit source]

Parameters

[edit | edit source]

Cavity Mirrors

[edit | edit source]

Upstream

Mirror Range (µm) Offset (µm) X Y
M1 2.1mm ? 90 -100
M2 1.6mm (default) 0 0 0
M3 1.2mm ? -150 -50
M4 0.9mm 2.5–5.5 ? -180 -190
M5 3.7mm R=3820 ? -70 -290
M6 2.8mm ? 70 -230

Downstream

Mirror Range (µm) Offset (µm)
M1 Cu 2.75m 5–45 0
M2 2.65-3.15 2.65–3.15 -230
M3 Cu 2.75m 5–45 -520
M4 3.5mu 3.15–3.9 320
M5 Cu 3.75m ? ?
M6 3.9-4.9mu 3.9–4.9 -140

Undulator move parameters

[edit | edit source]

See feluc for more general information on undulator.

Nominal value for velocity -> Vel(mm/s) 0.300

This can be changed, but due to resonances, not all values work well.
FAST 0.600 and 0.900 are good
SLOW 0.01, 0.02 and 0.06 are good
0.03, 0.04 and 0.05 are not good