From HFML-FELIX Wiki
Jump to: navigation, search
FEL2
Beam
Energy 45 MeV
Undulator
period (λu) 65 mm
no. periods 38
KRMS (range) 0.4–1.9

FELIX-2, or FEL2, is the mid-Infrared or short-wavelength beam line of FELIX operating from 3–45 µm.

Spectral Range vs. Beam Energy

[edit | edit source]
Beam Energy [MeV] Min [µm] Max [µm] Min [cm-1] Max [cm-1] Max pulse width [µs]
25 10 29 350 1000 10
35 5 15.5 650 2000 10
45 3 9.3 1075 3333 10


Old undulator:

Typical power curve for 45 MeV at 1.7 λ detuning.
Beam Energy [MeV] Min [µm] Max [µm] Min [cm-1] Max [cm-1] Max pulse width [µs]
27.5 13.1 50 200 763 12
30 11 42 238 909 12
31.4 10.1 38.5 259 990 11
38 6.9 26.3 380 1449 10
44 5.5 19.6 510 1818 9
45.5 5 18.3 545 2000 8
47 4.8 17 588 2083 8

Procedures

[edit | edit source]

Parameters

[edit | edit source]

Cavity Mirrors

[edit | edit source]

Upstream

Mirror Range (µm) Offset (µm) X Y
M1 2.1mm ? 90 -100
M2 1.6mm (default) 0 0 0
M3 1.2mm ? -150 -50
M4 0.9mm 2.5–5.5 ? -180 -190
M5 3.7mm R=3820 ? -70 -290
M6 2.8mm ? 70 -230


Downstream

Mirror Range (µm) Offset (µm)
M1 MED1 2.76m (default) 2.5–45 0
M2 HOLE
M3 Empty
M4 MED5 2.87m ?
M5 HOLE
M6 MED6 2.76m 2.5–45 ?

Undulator move parameters

[edit | edit source]

See feluc for more general information on undulator.

Nominal value for velocity -> Vel(mm/s) 0.300

This can be changed, but due to resonances, not all values work well.
FAST 0.600 and 0.900 are good
SLOW 0.01, 0.02 and 0.06 are good
0.03, 0.04 and 0.05 are not good