From HFML-FELIX Wiki
Jump to: navigation, search

LabVIEW uses cameras using the GigE Vision standard. We have several types listed in order of age (oldest first):

  • Leutron Vision PicSight P34M-GigE
  • JAI Ltd., Japan CM-030GE
  • Allied Vision Technologies Manta_G-031B (E0020014)

The Leutron and JAI cameras can remember their name using the non-volatile memory of the camera itself. The Manta cameras cannot. NI-MAX will issue a 'random/sequential' name to each Manta cam. It stores these names in text files in the Public folder. Therefore, to keep the name of Manta cams identical across computers, you could copy the predefined files from this location S:\Flare\NI MAX camera definition files' to C:\Users\Public\Documents\National Instruments\NI-IMAQdx\Data on new or newly installed computers.


Camera number Location Type Serial DNS (@fxmnet) IP LED installed?
1 in between buncher and accelerator unknown (dead) camera1 N/A N/A unknown
2 before the first dipole Leutron 1866019D10 camera2 192.168.14.22 yes
3 before the second dipole Leutron 1866019D11 camera3 192.168.14.23 yes
4 near the upstream vacuum chamber Manta F314D0F9B mantacam1 192.168.14.180 NO
5 entry of the undulator Leutron 1866019D13 camera5 192.168.14.25 yes
6 midway in the undulator Leutron 1866019D14 camera6 192.168.14.26 yes
7 exit of the undulator Manta F314D0F9D mantacam3 192.168.14.182 yes
8 towards the dump Manta F314D0F9E mantacam4 192.168.14.183 yes
9 near the downstream vacuum chamber Manta F314CD124 mantacam0 192.168.14.179 NO