See the RI FLARE LINAC Manual[1], and also the PPT Manual Electron Source[2] for background and safety steps.

Steps:

  • At FLARE HV deck
    • disconnect and ground the HV capacitor
  • At the high voltage power supply (FTA, top level, all the way in the back)
    • Set the current and voltage both to zero
    • Set the mode to local
    • Turn the key to conditioning mode
  • At the FLARE console
    • release the BEAM interlock
    • in the Beam optics and Vacuum program, check that you are Master, and enable the reset button
  • At the high voltage power supply:
    • set voltage to 100 kV
    • slowly increase current until HV trips (sparks)
      • reset e-source error and wait until power supply turns on again
    • wait until no more trips occur for a given current
    • keep increasing current slowly when the HV has become stable
    • for instance, 1 µA, 2 µA, 4 µA, 10 µA, 20 µA, 40µA, 70 µA, 100 µA, 130 µA, 160 µA etc.
    • At (at 100 kV), the power supply will switch from CC to CV, and conditioning is complete.
      • On the cathode installed in Feb. 2019, this required around 800 µA of current.
    • switch the key back from conditioning to normal mode
    • (optionally:) On linac-control, run Autohotkey script to keep pressing shift-f4 (will reset e-source error) on the "e-source HMI" to automate cycle. Otherwise you will be spending a lot of time in the FTA pressing the reset button over and over again. Do keep an eye on the process if you decide to go this way.
  • At the FLARE HV Deck
    • unground the capacitor and reconnect to HV deck.