From HFML-FELIX Wiki
Historic See Operation#Procedures for the most recent version |
- Controlroom FELIX console
- Turn off GUN RF TIMING ON
- Turn off 3 GHZ RF TIMING ON
- If FELICE is not running:
- Turn off GUN HV ON
- Turn off GUN RF ENABLE
- Turn off 3 GHZ ENABLE
- Turn off CHARGE MODULATOR
- Turn off SLINGERCIRCUIT ON
- Close vacuum line 1 or 2B
- Set the timer FELIX BEAM PULSE to 2 µs
- Set Repetition rate to 1 Hz
- Set Repetition rate to 1 Hz
- If beam line was FEL2:
- If FELICE is running:
- Turn off timer S2 FELIX accel SP 2
- If FELICE is not running:
- Controlroom Building console
- Controlroom FLARE console
- If FLARE is off:
- Turn off the FLARE solenoids
- If FELICE is off: proceed to FTA
- proceed to FTA Fel Technical Area modulator cabinets and repeat for both modulators (East and West):
- Push LOCAL to select local control
- Turn off high voltage
- Turn off line
- Turn off klystron
- Turn off cooling
- Turn off the high voltage power supplies (two per modulator)
- FTA COFFEE cabinet
- Turn off the East 3 GHz amplifier (round green power button)
- Turn off the gun RF amplifier and power supply
- Turn off the prebuncher power supply
- FTA near exit:
- Turn off the West 3 GHz amplifier (round green power button) high on the wall
- Turn off the beam optics magnet power supplies (square green buttons)
- Turn of the lights in FTA
- proceed to FTA Fel Technical Area modulator cabinets and repeat for both modulators (East and West):
- If FLARE is off:
- FX0 Building lighting console
- If you are the last to leave:
- Turn off all the lights
- If another operator is present: check that the other operator knows how to turn off the lights
- If you are the last to leave: