wnd = software window

Step Where can I find that? Action Details
1 Main panel Switch on all 5 FELIX & Felice buttons



2 FELIX User Station (wnd ) Select the correct user station



Select 25 MHz or 1 GHz
3 FELIX_dump_line_L2 (wnd) Find or Load a previous dump-line setting for E-range


4 Find or Load the same setting in low-lever RF phases
5 Magneetslingercircuit (wnd) Change current to match 2B20-25
6 Gun > Felix (wnd) Change gun bias to ~170.5 V @ 25 MHz or ~80 V @ 1 GHz. Precise number can be found in the file name
7 HPRF.vi (wnd) Check the file has correctly loaded in the HPRF window. Set values to match the yellow values
8 Main panel Switch the “3GHz RF timing on” button on
9 low level RF phases (wnd) Set klystron modulators to target values (from file name). Step is 4kV - 5kV. Press ‘feedback’ off, and ‘zero’.
10 on Flare interface computer If FLARE solenoids are off, switch them on.


11 LLRF power (wnd) press ‘feedback’ off, and ‘zero’ all.
12 Felix Timers (wnd) Check timer S1 = 2µs and rep. rate = 1Hz. Open vacuum system.
13 OC Control (wnd) Insert BS, and align cavity mirrors. Watch 2S21, align downstream. Watch 2S41, align upstream. Remove BS.


14 Main panel Press ‘GUN RF timing on’.
15 Felix dump line L2 (wnd) Optimize e- path. Align with indicator. PM10 = SX10. PM20 = SX11. PM30 = SX30* (fault with blue, align 1 square below indicator). PM40 = SX40. PM50 = SX55. PM60 = SX70. Slowly ramp to 10µs / 10Hz, ensure all e- are dumped.
16 low level RF phases (wnd ) Fine-tune low level RF phases. Once done, press ‘zero’, ‘load’, and ‘feedback on’ in all.
17 At diagnostic station switch amplifier to x1 (@1GHz) or x10 (@25MHz).
18 Gun / prebuncher Felix (wnd) Adjust gun bias to achieve 360mV @25MHz / 200mV @1GHz (yellow curve on scope)
19 OC control Felix (wnd ) Find cavity zero. Set ‘dt_CLdetuning’ to zero, and adjust “DT_CLzero” close to an unstable state. Then, reset ‘dt_CLdetuning’ to 1.8.
20 uc-flx-gui (wnd) Calibrate λ. Go to calc, and set lambda to correct live value.