| runs control software for FELIX optical cavity | |
| Location | |
|---|---|
| room | FX-2.35 |
| rack | unknown |
| Hardware | |
| model | Arcobel PC |
| Details | |
| Software |
|
| Ethernet device | |
| Location | |
|---|---|
| Room | FX-2.35 |
| IP | |
| DNS name | felocx.science.ru.nl |
| Network | Machine network |
| IP | 192.168.14.106 |
| MAC | 00:01:29:1b:d3:a1 |
| Outlet | 135-01-19-15 |
| Switch port | as-135-1/5/0/27 |
FELOCX is the server that runs the control software for the FELIX optical cavity.
FELOCX
[edit | edit source]This machine drives the FELIX optical cavity system. The installation of the standard Windows 11 and LabView2011 has been done according to Installation_instructions_for_FELIX_LabView_Servers.
Software for the Optical Cavity
[edit | edit source]The software for the Optical Cavity can be found at \\felixdisk\felix1\FFsoftware\OC_felix\OX_oc_felix_development\OC_LabVIEW_2011\OX_oc_felix\builds\Optical Cavity Systems\ This whole folder needs to be copied to the C:\ disk.
The Agilent software needs to be installed and can be found at \\felixdisk\felix1\FFsoftware\OC_felix\OX_oc_felix_development\OC_LabVIEW_2011\OX_oc_felix\OC and OX_LV2011\Agilent\N1231_windows7_8_10\Agilent_KeySight Interferometer N1231B\N1231-13612\. The license is there as well. Install the x64 version. Also, from the /Drivers folder, install the drivers for the card. This can be done from device manager -> device -> update driver -> point to the driver folder.
Load configuration
[edit | edit source]There is a file (TODO: which? where?) containing the NI MAX configuration for all the pxi cards.
- Import the configuration file
- Check the names of the two relay cards:
- SW1 has serial 0x12541F9
- SW2 has serial 0x194A6CB
- For each of the NI Motion cards:
- TODO: put here the serial numbers of the cards, and write down the name of each set with that serial number!!!!
- load the correspondingly named Configuration Set
- Initialize the card
Further configuration information:
PXI-7340 -> (Board ID 3) -> Motor card 3 -> Device serial number 126722A PXI-7344 -> (Board ID 2) -> Motor card 2 -> Device serial number 1149004 PXI-7344 -> (Board ID 1) -> Motor card 1 -> Device serial number 1148FFC PXI-2566 "OX_SW1" -> Device serial number (0x)12541F9 PXI-2566 "OX_SW2" -> Device serial number (0x)194A6CB
Further configuration
[edit | edit source]When everything works and is functional, create a "service" in FireDaemon to have the subsystem start automatically.